| Created | 06/02/2021 | Updated | 12/17/2021 |
| Description | When the E2B (R3) metadata is pulled, the Message Sender Identifier (N.2.r.2) and Message Receiver Identifier (N.2.r.3) static values are switched. | | |
| Impacted Capabilities | Inquiry Management | Affected Apps | Medical Information Cloud - Classic Medical Information Cloud - Lightning |
| Affects Versions | V8, V9, MIC V10 | Fix Version | MIC V11 |
| Steps to Reproduce | 1. Navigate to the list of MED_E2B_Field_Mapping__mdt custom metadata records, and set different values for MED_Value__c on the N.2.r.2 and N.2.r.3 records. 2. Generate an E2B file. 3. View the file. The Message Sender Identifier (N.2.r.2) and Message Receiver Identifier (N.2.r.3) values display in the wrong location. Specifically, the value you set on the N.2.r.2 record displays where the N.2.r.3 value should be used, and the value you set for N.2.r.3 displays where the N.2.r.2 value should be used. | | |
| Workaround | 1. Navigate to the list records for the MED_E2B_Field_Mapping__mdt custom metadata. 2. Open the N.2.r.2 record in edit mode, and replace the value for MED_Value__c with the intended recipient of the transmission of the ICSR reports. Click Save. 3. Open the N.2.r.3 record in edit mode, and replace the value for MED_Value__c with the creator of the ICSR reports. Click Save. | | |