Skip to main content

KI-124

Created date06/27/2024Updated date06/27/2024
StatusBacklogRelated work itemMIC-3800
DescriptionIf a customer has more than 1,000 products, attempting to load the AdHoc QA page will result in an error of Collection size 1,204 exceeds maximum size of 1,000. This is due to a Salesforce picklist limit in Visualforce. For more information, reference Salesforce's documentation.
Affects version(s)MIC - all versionsImpacted capabilitiesInquiry Management
Steps to reproduce1. Load 1,001 general product records. 2. Open the AdHoc QA page. 3. Observe the error.
WorkaroundTo avoid this error, limit the number of products and general products available to any given country to less than 1,000. Alternatively, remove the Product field from the layout and do not use it as a filter.
Fix versionTBDResolution notesN/A